What is a Johnson Air Rotation® System?



Heating



Specifications for Heating

Heating Unit Features

Heating Efficiency Comparison



Cooling



Specifications for Cooling

Cooling Unit Features

Cooling Efficiency Comparison



Heating & Cooling

Specifications

Unit Features

Efficiency Comparison



Johnson Air Rotation® 
Optional Features




Industry-Specific Applications

Johnson Air Rotation® Optional Features

The Air Rotation® design is the perfect way to provide a complete solution to any large, open building. The Air Rotation® system comes with a variety of features and options:

  1. Evaporative Cooling
  2. Sound Reduction Package
  3. Humidification
  4. Oil Mist Filters
  5. Specialty Filtration
  6. Roll Filters
  7. Stainless Steel Flue
  8. Condensate Control Package
  9. Night Setback Package
  10. Start-up Testing and Adjustments
  11. Building Ventilation System Review
  12. MWA, Supply and Exhaust Fans
  13. Low NOx Burner
  14. Smoke Detectors
  15. Access Light Fixture
  16. Economizer Option
  17. Electronic Control Package
  18. Adjustable Horizontal and Vertical Louvers
  19. Access Platforms
  20. Unit-Mounted Ultra Violet (UV) Light (kills bacteria)

Johnson's Total SOLUTIONT combines one or more Johnson Air Rotation® units with our DragonT (Industrial Space Heater), FirefoxT (100% Make-up Air with heating and/or cooling) 80/20 PRT (80/20% Make-up Air with building pressurization and recirculation), or MarCraft® Custom Air Handling capabilities to provide any combination of HVAC equipment necessary to meet your needs.

Johnson's Total SOLUTIONT can meet any HVAC need by combining one or more Air Rotation® unit with our other products:

  1. DragonT Industrial Space Heater
  2. FirefoxT (100% make-up air with heating and/or cooling)
  3. 80/20 PRT (80/20% make-up air with building pressurization and recirculation)
  4. MarCraftT Custom Air Handling Capabilities

Fact Sheet
Industry-Specific Applications
In addition to the Johnson Air Rotation® Heating, Air Conditioning and Ventilation units, the Air Rotation® design is the perfect way to provide a complete solution to any large, open building! These are many of the options and features available in the Johnson Air Rotation® Family of Products.

Evaporative Cooling Option:
Utilizing direct evaporative cooling media (Munters GlasDEK) for outside air, Johnson Air Rotation® units provide nearly free cooling for many areas of the country. Better yet, we can add mechanical cooling as well in the same unit, providing perfect air conditioning in all weather conditions.

Sound Reduction Package:

Any space will benefit from the quiet operation of an Air Rotation® unit. The answer for sound sensitive applications is our sound reduction options including Johnson’s exclusive quiet custom fans, built in sound targets, perforated double wall construction, and sound attenuators.

Humidification:
Johnson Air Rotation® units can include built-in humidifiers using an existing source of building steam or even generate its own steam with a gas or electric steam generator, atomizing humidifier, or direct pressurized misters. And, of course, the Air Rotation® unit will ensure even humidity throughout the space.

Oil Mist Filters:
When a building has an oil mist or related problem, the solution does not have to be costly. Simply adding “oil” mist filters to the Air Rotation® design quickly and efficiently solves the problem. Maintenance is easier than any other system by far, as the filters are indoor at ground or floor level.

Specialty Filtration Options:

Optional roll filters are perfect for textile and other industries with heavy amounts of particles in the space. Filters as fine as MERV 11 are available on the Air Rotation® unit. Even carbon-impregnated media solves odor problems. Who else offers this many choices?

Need to Catch a Flue?
Perfectly matched to our indirect-fired heater and your building, our double wall, UL® listed, stainless steel flue will last a lifetime and meet all local codes. Why risk buying anything else? You could catch something worse than our Flue!

If Steel Storage/Distribution is your game…
The Johnson Air Rotation® System with our Condensate Control Package could save the day (and a building full of steel). If the relative humidity is in the danger zone for steel storage, our Air Rotation® unit goes into action---lowering the relative humidity and sending an alarm to the potential destructive situation.

Night Setback: Nighttime Free Cooling
How to make the most efficient system even better? Add a Night Setback Package. For a few dollars more, the money saved with this option is yours to keep year after year. An adjustable setback and timer are fully adjustable for your specific schedule.

Now that you have bought the best…
Have the most experienced company start-up technician, test and adjust the unit at your facility. We’ve already solved nearly every conceivable situation quickly and efficiently in the past 83 years of jobsite start-ups. Why not guarantee the system is operating perfectly?

Need Lots of Ventilation?
Turn your Air Rotation® unit into a Building Ventilation System! The large volume fans in our unit can be used as either make-up air or exhaust fans as well. Have our engineering team review your building for this great design option.

MWA, Supply and Exhaust Fans:

Our Johnson Air Rotation® System will turn the air in your building several times each hour. If your building needs additional ventilation, we can supply it.

California Here We Come…
When tight emission guidelines require an ultra clean burning system, our Low NOx Burner option meets the challenge. Available on any size unit, this option is a must-have for states leading the country in tight emission standards.

Smoke Detectors:
Tied into a fire protection system or simply to alert the building occupants early, our Smoke Detector option can save more than the day.

Shed Light on the Solution:
An access light fixture inside the Air Rotation® unit is on every maintenance person’s wish list. How better to show off how well maintained the unit is!

It’s an Economizer:
Not only can the Air Rotation® unit handle fixed amounts of outside air with our original, coveted design, cooling units can be arranged with A-Frame Coils when an economizer option is used. This can provide high volumes of ventilation air for free cooling in the Spring and Autumn months.

Electronic Control Package…
…can tie into a building management system or just exhaust fans. Many building owners use this package with the Nighttime Free Cooling concept. The control package automatically ventilates the building at night, when the outside air is coolest. In the morning the building is closed up and that cool air is circulated all day – eliminating the need for air conditioning well into the afternoon, maybe all day!

Adjustable Horizontal & Vertical Louvers:
You may not notice, but our design engineers probably already analyzed your building and included horizontal and/or vertical directional louvers needed at the unit outlet. This is what makes the Air Rotation® concept work so well. Wonder why our competitors don’t even offer louvers as an option? We sure have.

Access Platforms:
Making burner maintenance and start-up safer and more convenient, access platforms are a great option for indoor and outdoor Air Rotation® units.

UV Kills (bacteria):
Unit-mounted UV Lights in the Air Rotation® unit eliminates the possibility of Sick Building Syndrome when applied properly. Let our design experts show you the advantages a UV Light System can bring.

Johnson’s Total SOLUTION? combines one or more Johnson Air Rotation® units with our Dragon® (Industrial Space Heater), Firefox® (100% Make-up Air with heating and/or cooling) PR® (80/20% Make-up Air with building pressurization and recirculation), or MarCraft Custom Air Handling capabilities to provide any combination of HVAC equipment necessary to meet your needs.